Conceptual, basic and detail engineering
P&IDs, hydraulic drawings, calculations, technical specs and datasheets for critical equipment.
5 pillars covering the full project lifecycle: from conceptual engineering to predictive maintenance. Each pillar complies with the applicable standards (NFPA, FM Global, APSAD) based on jurisdiction and insurer requirements.
We design fixed suppression systems to the standards required by international insurers. We support clients from concept stage to commissioning.
P&IDs, hydraulic drawings, calculations, technical specs and datasheets for critical equipment.
Specialised software (Elite Software, PipeFlow, Sprinkcalc) to size sprinkler, hydrant and monitor networks.
Technical assessment against FM Global Data Sheets, applicable NFPA and insurer requirements (Allianz, Mapfre, HDI).
Full project responsibility — engineering, procurement, construction, commissioning and documented handover.
The most critical asset of an industrial plant is its fire pump room. We design, fabricate and install integrated pump rooms per NFPA 20 with FM Approved / UL Listed equipment.
Main + backup + jockey pump. Diesel/electric/hybrid. Vertical or horizontal reserve tanks depending on available layout.
Wet, Dry, Preaction, Deluge and ESFR based on occupancy. Hydraulic calculation included per NFPA 13.
High, medium and low expansion for hydrocarbon tanks, containment dikes, chemical plants and hangars.
NFPA 15 — protection for transformers, storage tanks and critical equipment.
For assets that cannot tolerate water damage (data centers, control rooms, electrical substations, libraries) we design clean agent suppression systems certified per NFPA 2001 and ISO 14520.
Latest generation agent with Global Warming Potential ~1. Ideal for data centers and critical technical rooms.
Proven solution with over 30 years of history in industrial control rooms.
Paint booths, turbines, generators. Concentration calculation per NFPA 12.
Natural inert gas, zero environmental impact. APSAD approved (France).
Fixed and mobile systems for class B and K hazards in industrial kitchens.
The detector is the first line of defense. We design and integrate early detection systems with ATEX classification for explosive atmospheres.
Point and linear detectors per NFPA 72. Temperature compensation for ambient conditions.
For hydrocarbons, hydrogen and solvents. Field-validated detection distances.
H2S, CH4, CO, NH3, hydrocarbon mixtures. SIL2/SIL3 certification per LOPA analysis.
Interlocks with process shutdowns and emergency ventilation. Modbus, HART, PROFIBUS protocols.
A poorly maintained system is as dangerous as no system at all. We offer preventive and corrective maintenance contracts per NFPA 25 with quarterly, semi-annual and annual schedules.
Annual verification of operating point — flow, pressure, automatic start (NFPA 25 ch. 8).
Novec 1230, FM-200, Inergen. Purity and weight analysis before recharge.
Sprinklers, hydrants, hoses, signage. Photographic report with corrective actions.
Issuance of technical certificate signed by licensed professional for insurance submission.
Our engineering team advises you at no cost on the right technical solution and applicable regulatory compliance.
Request technical quote